4.17.39 CTI_IE_STATION_INFO

Description

Data of a PBX station.

Attributes

Id

Unique ID station – hexadecimal number.

Name

Name of the station – string.

Contact.Scheme

Scheme of external address – see CTI_IE_CALLING_ADDRESS.

Contact.Prefix

Prefix ID of telephone number of station. It is necessary to see prefixes from NS.

Contact.pInfo

Telephone number of station – string. Station is external or internal according to StationClass.

InternalNumber

Internal telephone number of the station – string. If not in the database this attribute might not be present in the information element.

ExternalAddress.Attr.Scheme

Scheme of the external address – see CTI_IE_CALLING_ADDRESS.

ExternalAddress.Attr.Type

Type of external address, so-far defined only for telephone numbers, makes no sense for URL – see CTI_IE_CALLING_ADDRESS.

ExternalAddress.pInfo

Own external address (telephone number) – string. Used only when Flag EXTERNAL (2) is initiated. If not in the database this attribute might not be present in the information element.

UserId

ID of a user who owns the station – decimal number. If the user has not been yet classified in any of the groups this attribute has value -1.

PropertiesId

Unique ID properties – hexadecimal number.

Owner.PortId

ID of the port, which owns the station – decimal number. If no port is assigned this attribute has the value -1.

Owner.

TerminalId

ID of the type of terminal (telephone) of the station – decimal number. If no terminal assigned this attribute has value -1.

Owner.Order

Order of the station on the given port – hexadecimal number.

RingGroup

ID of the ringing group of the station – decimal number. If no ringing group assigned the attribute has value -1.

Flags

Flags of the station – binary number shifted by 0 = station is active, by 1 = no ringing in case of calls to the user, by 2 = station is external, by 3 = operator station – number 1, by 4 = operator station – number 2, by 5 = this station is to be receiving SMS, by 6 = station type SIP.

TimerUserCall

Timer when calling the user (late routing).

TerminalType

Telephone type. Possible values are: NONE, ANALOG, ISDN, GSM, IP,

SIEMENS_OPTIPOINT_500_ENTRY, SIEMENS_OPTIPOINT_500_BASIC, SIEMENS_OPTIPOINT_500_STANDARD, SIEMENS_OPTIPOINT_500_ECONOMY, SIEMENS_OPTIPOINT_500_ADVANCE

LanguageId

Language ID of user – hex number (see CTI_GET_INSTALLED_LANGS_REQ).

 

<CTI_IE_STATION_INFO Id="0x0" Name="Novak kancelar" InternalNumber="200" ExternalAddress.Attr.Scheme="0" ExternalAddress.Attr.Type="1" UserId="0" PropertiesId="0x1A" Owner.PortId="1" Owner.TerminalId="0" Owner.Order="0x0" RingGroup="-1" Flags="0x9" TimerUserCall="0x0" TerminalType="ANALOG" LanguageId="0x405"/>