5. Technical parameters
Electric Parameters
Parameter | Value | Conditions |
Minimal off-hook line current | 15 mA | Off-hook |
Minimal on-hook line voltage | 22 V | Off-hook |
DC voltage drop (off-hook) | < 8 V< 16 V | I = 25 mA |
Off-hook resistance | >1MΩ | U = 25..100 V |
Off-hook AC impedance | 220 Ω + 820 Ω paral. 115 nF | 20 to 60 mA |
Return loss | > 14 dB | 20 to 60 mA |
Bandwidth | 300 to 3500 Hz | 20 to 60 mA |
Ringing impedance | > 2 kΩC = 0.47 μF | 25 to 50 Hz |
Ringing detector sensitivity | 10 to 20 V | 25 to 50 Hz |
Pulse dialing | 40 / 60 ms | |
DTMF dialing level | -9.0 +2.0/-2.5 dB a -11.0 dB +2.5/-2.0 dB | 20 to 60 mA |
Overvoltage protection – between A, B | 1000 V | 8 / 20 μs |
Notes:
1) Whichever ringing form is accepted.
Switch Parameters
- Minimum voltage: 9 V AC or DC
- Maximum voltage: 24V AC or DC
- Maximum current: 1A AC or DC
- Resistance – breaking: min. 400 kΩ
- Resistance – closing: cca 0,5 Ω
- Fuse: resettable
Other Parameters
- Universal dimensions: 65×130×24 mm
- Compact dimensions: 100×185×16 mm
- Working temperature range: -20 to +70 ˚C