4.12 CPC and P100

CPC

The are two CPC protocols: KONE and Antenna. These protocols can include 2N Ext, which completes the DATA (error) information with the shaft number and audio unit type.

The data message consists of:

Command – Call type – DATA – ID (974) – Axx (for 2N Ext only)

CPC KONE 2N Ext          
Call type Command Call type Data ID (974) 2N Ext
Alarm 04 10 0000000000000 parameter 974 Axx
Alarm 2 04 10 0000000000000 parameter 974 Axx
Checking call 04 21 0000000000000 parameter 974  
Rescue process ended 04 84 0000000000000 parameter 974 Ax
Button stuck 04 90 0000000000000 parameter 974 Axx
Button repaired 04 90 0000000000001 parameter 974 Axx
Replace battery 04 31 1510070000000 parameter 974  
Battery replaced 04 31 1510070000001 parameter 974  
Audio error 04 91 0000000000000 parameter 974 Axx
Audio repaired 04 91 0000000000001 parameter 974 Axx

Note Axx:

A – shaft and audio unit extension

Xx – shaft number

x– audio unit type (0 – cabin, 1 – machine room, 2 – shaft, 3 – cabin roof, 4 – cabin bottom, 5 – cabin 2, 6 – cabin 2 roof, 7 – cabin 2 bottom, 8 – fireman) 

Example

This is only a part of the data message, excluding the beginning, checksum and end.

  • 0490000000000000187654321A50 – Button repaired, identification number (parameter 974) 87654321, shaft 5, cabin audio unit

Warning

  • The Button repaired, Battery replaced and Audio repaired information is only transmitted via the 2N Ext protocol.
  • If the 2N Ext mode is not set, the operational call will not be established.
CPC Antenna 2N Ext          
Call type Command Call type Data ID (974) 2N Ext
Alarm 04 27 00000 parameter 974 Axx
Alarm 2 04 27 00000 parameter 974 Axx
Checking call 04 26 00000 parameter 974  
Rescue process ended 04 84 00000 parameter 974 Ax
Button stuck 04 90 00000 parameter 974 Axx
Button repaired 04 90 00001 parameter 974 Axx
Replace battery 04 17 00000 parameter 974  
Battery replaced 04 17 00001 parameter 974  
Audio error 04 91 00000 parameter 974 Axx
Audio repaired 04 91 00001 parameter 974 Axx

 

Note Axx:

A – shaft and audio unit extension

Xx – shaft number

x– audio unit type (0 – cabin, 1 – machine room, 2 – shaft, 3 – cabin roof, 4 – cabin bottom, 5 – cabin 2, 6 – cabin 2 roof, 7 – cabin 2 bottom, 8 – fireman)

Example

This is only a part of the data message, excluding the beginning, checksum and end.

  • 04910000087654321A45 – Audio error, identification number (parameter 974) 87654321, shaft 4, cabin 2 audio unit

Caution

  • The Button repaired, Battery replaced and Audio repaired information is only transmitted via the 2N Ext protocol.
  • If the 2N Ext mode is not set, the operational call will not be established.


P100

This protocol can also include 2N Ext, which completes the DATA (error) information with the shaft number and audio unit type.

The data message consists of:

Call type – ID (974) – DATA – Axx (for 2N Ext only)

P100        
Call type Call type ID (974) DATA 2N Ext
Alarm 1 parameter 974   Axx
Alarm 2 1 parameter 974   Axx
Checking call 3 parameter 974    
Rescue process ended 2 parameter 974 500 Ax
Button stuck 2 parameter 974 800 Axx
Button repaired 2 parameter 974 801 Axx
Replace battery 2 parameter 974 100  
Battery replaced 2 parameter 974 101  
Audio error 2 parameter 974 200 Axx
Audio repaired 2 parameter 974 201 Axx

Note Axx:

A – shaft and audio unit extension

Xx – shaft number

x– audio unit type (0 – cabin, 1 – machine room, 2 – shaft, 3 – cabin roof, 4 – cabin bottom, 5 – cabin 2, 6 – cabin 2 roof, 7 – cabin 2 bottom, 8 – fireman)

Example

This is only a part of the data message, excluding the beginning, checksum and end.

  • 287654321500A3 – Rescue process ended, identification number (parameter 974) 87654321, shaft 3

Caution

  • The Button repaired, Battery replaced and Audio repaired information is only transmitted via the 2N Ext protocol.
  • If the 2N Ext mode is not set, the operational call will not be established.