4.11 CPC and P100

CPC

The are two CPC protocols: KONE and Antenna. These protocols can include 2N Ext, which completes the DATA (error) information with the shaft number and audio unit type.

The data message consists of:

Command – Call type – DATA – ID (974) – Axx (for 2N Ext only)

CPC KONE 2N Ext




Call typeCommandCall typeDataID (974)2N Ext
Alarm04100000000000000parameter 974Axx
Alarm 204100000000000000parameter 974Axx
Checking call04210000000000000parameter 974
Rescue process ended04840000000000000parameter 974Ax
Button stuck04900000000000000parameter 974Axx
Button repaired04900000000000001parameter 974Axx
Replace battery04311510070000000parameter 974
Battery replaced04311510070000001parameter 974
Audio error04910000000000000parameter 974Axx
Audio repaired04910000000000001parameter 974Axx

Note Axx:

A – shaft and audio unit extension

Xx – shaft number

x– audio unit type (0 – cabin, 1 – machine room, 2 – shaft, 3 – cabin roof, 4 – cabin bottom, 5 – cabin 2, 6 – cabin 2 roof, 7 – cabin 2 bottom, 8 – fireman) 

Example

This is only a part of the data message, excluding the beginning, checksum and end.

  • 0490000000000000187654321A50 – Button repaired, identification number (parameter 974) 87654321, shaft 5, cabin audio unit

Warning

  • The Button repaired, Battery replaced and Audio repaired information is only transmitted via the 2N Ext protocol.
  • If the 2N Ext mode is not set, the operational call will not be established.
CPC Antenna 2N Ext




Call typeCommandCall typeDataID (974)2N Ext
Alarm042700000parameter 974Axx
Alarm 2042700000parameter 974Axx
Checking call042600000parameter 974
Rescue process ended048400000parameter 974Ax
Button stuck049000000parameter 974Axx
Button repaired049000001parameter 974Axx
Replace battery041700000parameter 974
Battery replaced041700001parameter 974
Audio error049100000parameter 974Axx
Audio repaired049100001parameter 974Axx

Note Axx:

A – shaft and audio unit extension

Xx – shaft number

x– audio unit type (0 – cabin, 1 – machine room, 2 – shaft, 3 – cabin roof, 4 – cabin bottom, 5 – cabin 2, 6 – cabin 2 roof, 7 – cabin 2 bottom, 8 – fireman)

Example

This is only a part of the data message, excluding the beginning, checksum and end.

  • 04910000087654321A45 – Audio error, identification number (parameter 974) 87654321, shaft 4, cabin 2 audio unit

Caution

  • The Button repaired, Battery replaced and Audio repaired information is only transmitted via the 2N Ext protocol.
  • If the 2N Ext mode is not set, the operational call will not be established.


P100

This protocol can also include 2N Ext, which completes the DATA (error) information with the shaft number and audio unit type.

The data message consists of:

Call type – ID (974) – DATA – Axx (for 2N Ext only)

P100



Call typeCall typeID (974)DATA2N Ext
Alarm1parameter 974
Axx
Alarm 21parameter 974
Axx
Checking call3parameter 974

Rescue process ended2parameter 974500Ax
Button stuck2parameter 974800Axx
Button repaired2parameter 974801Axx
Replace battery2parameter 974100
Battery replaced2parameter 974101
Audio error2parameter 974200Axx
Audio repaired2parameter 974201Axx

Note Axx:

A – shaft and audio unit extension

Xx – shaft number

x– audio unit type (0 – cabin, 1 – machine room, 2 – shaft, 3 – cabin roof, 4 – cabin bottom, 5 – cabin 2, 6 – cabin 2 roof, 7 – cabin 2 bottom, 8 – fireman)

Example

This is only a part of the data message, excluding the beginning, checksum and end.

  • 287654321500A3 – Rescue process ended, identification number (parameter 974) 87654321, shaft 3

Caution

  • The Button repaired, Battery replaced and Audio repaired information is only transmitted via the 2N Ext protocol.
  • If the 2N Ext mode is not set, the operational call will not be established.