3.2 Programming Using Lift DTMF config

Lift DMTF config is a 2N® Lift8 remote programming tool. It provides easy remote programming via a phone line. The Lift DMTF config tool does not have to be configured. It is suitable for programming of a stand-alone  2N® Lift8 device in particular.

To program identical parameters in multiple 2N® Lift8 devices, it is advisable to use the procedure in the text below – Lift config group.

Use

It is necessary to create a  *.csv configuration file including the required parameters to program 2N® Lift8 using Lift DTMF config successfully. 


Note

Enter lift_config.exe in the command row started in the folder with this file to display Help (for download here or at 2N.com).

Help also displays an example of the configuration file and the parameter writing format.

Example of Configuration File in Help

The configuration file can include any number of programmable parameters (except for parameters 1xxx and services 8xxx). Refer to Subs. 3.3 Table of Parameters for details.

Example of Configuration File

Having created the configuration file, start the command row in the directory where the file is located. Upload the configuration file into to same directory as the .csv file or specify the path to the file on the command row. After upload, enter the following into the command row:

lift_config.exe space [Options] (see below for the options) space [phone_number] (intercom contact number) space [cfg_file] (configuration filer name and .csv file type)

Example of Upload of Configuration File to Device

Options 

Command

Description

-sSet the SIP server. By default, port 5060 is used, if another port is requested, enter it (e.g. proxy.2n.com:5065) after the SIP server.
-uSet the SIP server user name.
-aSet the SIP server authorization name.
-lReset the remote lift unit password (parameter 991 – service password).
-rReset the device factory default values (full initialization does not delete parameters 1100–1115).
-tSet the user profile (parameter 850).
-pSet the SIP account password if authorization is required by the server.
-eSet the SIP server registration time limit (in seconds). The default value is 300 s.
-iSet the tool initialization time limit  (in seconds). The default value is 3 s.
-wSet the incoming call waiting timeout (in seconds). The range is 0–3600. The default value is 0 s – no waiting for an incoming call.

Lift config group

Bulk commands are advised for bulk programming of a group of 2N® Lift8 devices. It is necessary to:

  • complete a group configuration file with the configuration parameters (lift config group),
  • make a text file list of the phone numbers of the devices to be programmed.

Download group configuration file here Upload the configuration file into to same directory as the .txt file or specify the path to the file on the command row.


Lift config Group Configuration File Parameters

Edit and complete the following group configuration file parameters for successful programming:

  • sip_server
  • sip_username
  • sip_password
  • lift_pass
  • cfg_file – enter the configuration file name

Create a text file with a phone number list for the 2N® Lift8 devices to be programmed – one number per row.

Example of Phone Number Text File

Now start the command row in the folder with the above mentioned files to complete 2N® Lift8 programming. The starting command is:

lift_config_group.cmd space "[phone numbers file]" (name of the phone number list text file including the .txt file type, in quotation marks)

Example of Group Configuration Start via Command Row

Once the command is started, the command row writes out gradual connections to the phone numbers and their programming.